Bore Not Working Perth? Bore Pump Repairs | Aquarian

Bore Not Working Perth? Bore Pump Repairs & Fault Finding

Aquarian Drilling provides professional water bore fault finding, bore pump repairs and submersible pump replacement throughout Perth and surrounding areas.

If your water bore has stopped working, the problem needs to be diagnosed first. For example, your pump may run without producing water. It may also lose pressure or keep tripping the power.

A failed water bore does not automatically mean you need a new pump or a new bore.

Aquarian Drilling has been repairing and drilling water bores since 1994. Therefore, we have more than 30 years of experience with Perth groundwater systems.

Importantly, we understand the complete bore, pump and electrical system. This allows us to find the likely cause before recommending repairs.

Bore not working in Perth? Talk directly to Aquarian Drilling.

Steve Rowland – 0417 928 330
James Rowland – 0407 885 091

Bore Not Working Perth? Start With the Symptoms

A Perth water bore can stop working for many reasons.

The fault may be electrical or mechanical. However, the problem may also be within the bore itself. In some cases, the reticulation system is actually the cause.

Common bore problems include:

  • Bore completely dead
  • Pump running but no water
  • Bore pump tripping the power
  • Low water pressure
  • Reduced water flow
  • Pump humming but not starting
  • Pump starting and stopping
  • Bore producing sand
  • Dirty or discoloured bore water
  • Centrifugal pump losing prime
  • Pump controller faults
  • Stuck submersible pump
  • Bore gradually losing performance

If you have a bore not working in Perth, these symptoms provide useful clues. However, proper testing is still needed to find the actual fault.

Common Reasons a Perth Bore Stops Working

Different faults can produce very similar symptoms.

For this reason, we recommend diagnosing the system before replacing equipment.

Bore problemPossible causes
Bore completely deadPower supply, controller, cable, motor or pump fault
Pump runs but no waterPump, water level, rising main, non-return valve or bore problem
Pump trips the powerMotor, cable, capacitor, controller or electrical fault
Low water pressureWorn pump, leak, falling water level, reduced bore yield or reticulation
Pump hums but won’t startCapacitor, motor, electrical supply or mechanical fault
Pump starts and stopsController, protection device, water level or electrical problem
Water contains sandBore screen, casing, sediment or formation problem
Flow gradually decreasesBore fouling, screen blockage, pump wear or reduced bore performance
Centrifugal pump won’t draw waterLoss of prime, suction leak, foot valve or water-level problem

These are possible causes only. Therefore, the system should be tested before deciding what needs to be repaired.

Bore Pump Running but No Water?

Is your bore pump running but no water is coming out?

Do not immediately assume the pump needs replacing. Several faults can produce the same symptom.

Possible causes include:

  • Damaged rising main
  • Failed non-return valve
  • Worn or damaged pump
  • Low groundwater level
  • Pump above the pumping water level
  • Blocked or deteriorated bore screen
  • Reduced bore yield
  • Suction leak on a centrifugal system
  • Loss of prime
  • Reticulation or valve fault

When customers contact us about a bore not working Perth-wide, this is a common problem.

First, we need to determine where the water flow is being lost. The problem may be with the bore, pump or water delivery system.

Replacing a pump without finding the actual fault can result in unnecessary expense.

Bore Pump Tripping the Power or RCD?

A bore pump that repeatedly trips the circuit breaker, RCD or motor protection should be investigated.

Do not continually reset a circuit that keeps tripping.

Possible causes include:

  • Failed pump motor
  • Low motor insulation resistance
  • Damaged electrical cable
  • Water entering an electrical connection
  • Failed capacitor
  • Faulty contactor
  • Starter or controller fault
  • Motor overload
  • Seized pump
  • Electrical supply problem

Electrical testing can help locate the fault. For example, the problem may be in the pump motor, cable, controller or associated electrical equipment.

Aquarian Drilling combines water bore experience with specialist bore electrical knowledge. As a result, we can investigate both the pumping and electrical sides of the system.

If your bore is not working in Perth and the power keeps tripping, stop repeatedly resetting it. Instead, arrange proper fault finding.

For further information about RCDs and electrical safety, refer to the WA Government’s RCD safety guidance.

Bore Pump Humming but Not Pumping Water?

A humming pump can indicate that the motor has power but cannot start correctly.

On some single-phase systems, a failed capacitor can cause this problem.

However, other causes include:

  • Motor problems
  • Low voltage
  • Seized pump components
  • Electrical faults
  • Starter problems

Continuing to run a motor that cannot start may cause further damage.

Therefore, switch the system off and have the fault investigated.

Bore Has Low Water Pressure?

Low pressure is one of the most common water bore complaints.

However, low pressure does not automatically mean you need a new pump.

Possible causes include:

  • Worn pump components
  • Incorrect pump performance
  • Falling pumping water level
  • Reduced bore yield
  • Damaged rising main
  • Leaking pipework
  • Blocked bore screens
  • Iron or biological fouling
  • Partially closed or faulty valves
  • Reticulation problems

The fault needs to be traced through the complete system.

For example, installing a larger pump will not fix a bore that cannot sustainably supply the required water.

Likewise, a good bore and pump can still have poor pressure if there is a reticulation fault.

Bore Pump Starts and Stops Repeatedly

A bore pump that continually starts and stops should be investigated.

Frequent cycling can increase wear on the motor and electrical equipment. It can also indicate another problem within the system.

Possible causes include:

  • Controller problems
  • Electrical protection operating
  • Low groundwater level
  • Pump protection devices
  • Pressure control problems
  • Reticulation faults

The cause depends on the type of pumping system. Therefore, correct diagnosis is important before changing the pump or controller.

Submersible Bore Pump Replacement Perth

If testing confirms that your pump has failed, Aquarian Drilling provides professional submersible bore pump replacement across Perth and surrounding areas.

However, we do not simply replace the failed pump with another pump of the same size.

A replacement pump should suit the actual bore and system requirements.

Important factors include:

  • Total bore depth
  • Pump setting depth
  • Static water level
  • Pumping water level
  • Sustainable bore yield
  • Required water flow
  • Required pressure
  • Pipe size
  • Reticulation requirements
  • Electrical supply

Correct pump selection is important for performance and reliability.

A pump that is too small may not provide enough pressure or flow. On the other hand, an oversized pump can also cause problems.

For example, a pump should not continuously remove water faster than the bore can sustainably supply it.

Aquarian Drilling can assess the system and remove the failed pump. We can then recommend a suitable replacement.

Don’t Replace the Pump Until You Know Why It Failed

Before installing a replacement submersible pump, there is an important question:

Why did the old pump fail?

Simply installing another pump may not address the underlying problem.

Possible contributing factors include:

  • Motor electrical failure
  • Damaged electrical cable
  • Incorrect pump selection
  • Low water level
  • Pump running dry
  • Excessive cycling
  • Poor motor cooling
  • Voltage problems
  • Mechanical wear
  • Sand or sediment
  • Pump operating outside its suitable duty range

Where possible, we investigate the likely cause first.

As a result, we may identify another fault that should be corrected before the new pump is installed.

Bore Pump Electrical Testing & Repairs

Many water bore pump problems involve electrical components.

Aquarian Drilling provides specialist bore pump electrical fault finding and repairs.

Depending on the system, testing may include:

  • Pump motor testing
  • Insulation resistance testing
  • Electrical cable testing
  • Pump controller diagnosis
  • Capacitor testing
  • Starter and contactor testing
  • Motor protection
  • Electrical supply checks
  • Pump disconnection and reconnection

Correct testing helps identify which component has failed.

More importantly, it can prevent unnecessary replacement of a working pump.

Burnt-Out Bore Pump & Insurance Reports

Has your bore pump motor burnt out?

Some insurance policies may cover certain electric motor failures. However, cover depends on the individual policy and cause of failure.

Aquarian Drilling can provide bore pump testing and failure reports for insurance purposes where appropriate.

Customers should check their Product Disclosure Statement or contact their insurer to confirm cover.

Stuck Submersible Bore Pump?

A failed submersible pump is not always easy to remove.

Pumps can become stuck for several reasons, including:

  • Sediment build-up
  • Damaged casing
  • Tree roots
  • Electrical cable becoming wedged
  • Rising main problems
  • Pump position
  • Bore misalignment
  • Foreign material within the bore

Aquarian Drilling has experience with stuck bore pump recovery.

Pump recovery should be approached carefully. Excessive pulling force can damage the pipework, pump or bore casing.

In addition, previous attempts to remove the pump can sometimes make recovery more difficult.

For this reason, we assess the situation and risks before recommending a recovery method.

Pump Working but Bore Has Lost Water Flow?

Sometimes the pump is not the problem.

A bore can gradually lose performance because of changes within the bore or surrounding formation.

Possible causes include:

  • Sediment build-up
  • Blocked bore screens
  • Mineral deposits
  • Iron fouling
  • Biological growth
  • Deteriorated bore components
  • Changes in groundwater conditions

Depending on the bore construction, bore redevelopment may help restore lost performance.

Treatment may include air-lift development, mechanical cleaning or specialised chemical treatment.

However, every bore is different. Therefore, we assess the cause before recommending a redevelopment method.

Bore Producing Sand?

Sand entering a bore system should be investigated.

Possible causes include problems with the bore screen, gravel pack, casing or surrounding formation.

In addition, sand can damage pumping equipment over time.

The correct repair depends on the bore construction and source of the sand. Therefore, the bore should be assessed before simply replacing the pump.

Old Centrifugal Bore Pump Not Working?

Not every Perth water bore uses a submersible pump.

Many established Perth properties have older concrete wells fitted with surface-mounted centrifugal pumps.

Aquarian Drilling has extensive experience diagnosing and repairing these older systems.

Common problems include:

  • Pump losing prime
  • Suction leaks
  • Failed non-return or foot valves
  • Worn centrifugal pumps
  • Electrical faults
  • Poor water flow
  • Suction problems
  • Deteriorated bore spears

An old well does not automatically need replacing.

Where practical and economical, we investigate whether the existing well can be repaired, re-speared or restored.

However, some systems eventually reach the point where repair is no longer economical.

In these cases, we can provide options for a new submersible water bore and pump system.

Bore, Pump, Electrical or Reticulation Fault?

Correct diagnosis is particularly important with a bore not working in Perth.

The problem may be in one part of the system while the other components are working correctly.

Bore Problems

These can include reduced yield, blocked screens, sediment, fouling or deterioration.

Pump Problems

These can include mechanical wear, damage, incorrect performance or motor failure.

Electrical Problems

Possible faults include the motor, cable, capacitor, starter, contactor, controller or protection equipment.

Pipework Problems

Leaks, damaged rising mains and failed valves can reduce flow or pressure.

Reticulation Problems

Solenoid valves, controllers, field wiring and irrigation faults can sometimes make a working bore appear faulty.

Therefore, replacing components without proper fault finding can waste money.

Bore Not Working Perth – Our Fault-Finding Process

When investigating a bore not working across Perth, we work through the system logically.

The aim is to identify the likely cause before recommending repairs.

1. Understand the Symptoms

First, we establish what the bore is doing.

Does the pump run? Does the power trip? Is there water but poor pressure?

We also determine whether the problem occurred suddenly or gradually.

2. Check the Electrical System

Where appropriate, we test the pump motor, cable, controls and associated electrical equipment.

This can identify many common pump and electrical faults.

3. Assess Pump Operation

Next, we consider whether the pump is operating correctly.

We can also assess whether its performance suits the bore and system requirements.

4. Investigate the Bore & Water Supply

If necessary, we consider the water level, bore yield and bore condition.

These factors can help determine whether the pump or bore is responsible for the problem.

5. Recommend the Most Practical Repair

Once we identify the likely fault, we explain the available options.

Depending on the problem, this may involve a repair, pump replacement, bore redevelopment or another solution.

We diagnose first and replace only what needs replacing.

Why Choose Aquarian Drilling for Bore Repairs?

Established in 1994

Aquarian Drilling has more than 30 years of water bore drilling and repair experience in Western Australia.

Bore, Pump & Electrical Knowledge

We understand the complete water bore system.

Therefore, we can investigate the bore, pump and electrical installation rather than focusing on only one component.

Specialist Bore Electrical Experience

Electrical faults are common in bore pumping systems.

Our in-house electrical expertise allows us to investigate these problems correctly.

Repair Before Replacement

A bore that stops working does not automatically need a new bore or pump.

Where practical and economical, we investigate repair options first.

Submersible & Centrifugal Systems

We work with modern submersible bores and older centrifugal pump systems.

We also repair older-style concrete wells found throughout established Perth suburbs.

Deal Directly With the People Doing the Work

Aquarian Drilling is a family-owned and operated Western Australian business.

You deal directly with experienced people involved in assessing and carrying out the work.

Meet the Aquarian Drilling Team

Steve Rowland – Water Bore Driller

He is the Managing Director of Aquarian Drilling and holds WA Waterwell Driller’s Permit No. 217.

Steve has decades of hands-on experience with water bores.

His experience includes drilling, bore construction, development, redevelopment and complex repairs.

James Rowland – Bore Specialist & Licensed Electrical Contractor

James Rowland specialises in bore pumps and electrical systems. He is also a Licensed Electrical Contractor – EC 13614.

His experience includes submersible pumps, centrifugal pumps and motor testing. In addition, he provides electrical fault finding, pump controls and bore system troubleshooting.

Together, Steve and James provide bore, pump and electrical expertise within the same family team.

Bore Repairs Across Perth

Aquarian Drilling provides water bore repairs, pump fault finding and submersible pump replacement throughout Perth and surrounding areas.

We service Perth’s northern and southern suburbs, eastern metropolitan areas, the Perth Hills and surrounding districts.

If you have a bore not working in Perth, contact us and describe what the system is doing.

Helpful information includes:

  • Whether the pump starts
  • Whether water is flowing
  • Whether the power trips
  • Whether pressure has dropped
  • Whether the fault occurred suddenly or gradually
  • Whether you have a submersible or centrifugal pump
  • Approximately how old the system is

Don’t worry if you don’t know all the answers.

We can help determine what needs to be checked.

Frequently Asked Questions About Bore Problems

Why has my bore suddenly stopped working?

The problem could be electrical, mechanical or related to the bore itself.

Common causes include a failed pump motor, damaged cable, capacitor, controller or rising main. Reduced groundwater supply can also cause problems.

Testing is the best way to determine the actual cause.

Why is my bore pump running but no water is coming out?

Possible causes include a damaged rising main, failed non-return valve or worn pump.

Low water levels or a problem with the bore can also cause this symptom.

The system needs to be assessed to determine where the water flow is being lost.

Why does my bore pump keep tripping the power?

Repeated electrical tripping may indicate a fault with the pump motor, cable or controller.

Other electrical components can also cause the problem.

Do not continually reset a circuit that keeps tripping.

Why does my bore pump hum but not start?

A failed capacitor can cause this symptom on some single-phase pump systems.

However, motor, electrical supply or mechanical problems can produce similar symptoms.

Why has my bore lost pressure?

Low pressure can be caused by pump wear, leaking pipework or falling groundwater levels.

Reduced bore yield and reticulation problems are also possible causes.

Therefore, the complete system should be assessed before replacing the pump.

Can you replace my submersible bore pump?

Yes.

Aquarian Drilling provides submersible bore pump replacement across Perth and surrounding areas.

We can assess the existing system and recommend a pump suited to the bore and required duty.

Should I replace my bore pump with the same model?

Not necessarily.

The replacement pump should suit the bore depth, pumping water level and sustainable yield.

It should also provide the required flow and pressure.

In some cases, the existing pump may not have been correctly selected.

Can a failed bore pump be repaired?

Sometimes.

Whether repair is practical depends on the pump, motor, type of failure and age.

Availability of replacement components is also important.

In some cases, pump replacement is more economical.

Does a failed pump mean I need a new bore?

No.

The bore and pump are separate parts of the system.

If the bore remains serviceable, repairing or replacing the pumping equipment may restore the water supply.

Can an old concrete well be repaired?

Often, yes.

Many older Perth wells can be repaired, re-speared or restored. However, this depends on their construction and condition.

Can a bore that has lost flow be restored?

Possibly.

If fouling, sediment or screen blockage has reduced the flow, bore redevelopment may improve performance.

However, the cause needs to be assessed first.

Do you repair bore pumps throughout Perth?

Yes.

Aquarian Drilling provides bore repairs, pump fault finding and submersible pump replacement throughout Perth, the Perth Hills and surrounding areas.

Bore Not Working in Perth? Talk to Aquarian Drilling

If you have a bore not working in Perth, talk directly to Aquarian Drilling.

We can investigate a water bore that has stopped working, lost pressure, started tripping the power or stopped producing water.

We also provide professional submersible bore pump replacement when testing confirms that the pump has failed.

Most importantly, we diagnose the bore, pump and electrical system before recommending what needs to be repaired.

Aquarian Drilling Pty Ltd
Perth Water Bore Repairs, Pumps & Drilling
Family-Owned & Operated Since 1994

Steve Rowland – 0417 928 330
James Rowland – 0407 885 091

Servicing Perth, Perth Hills and surrounding areas

aquarian@iinet.net.au